A complete range of VKF/AEAI-certified technical solutions to secure your buildings, from design to installation.
Every cable, pipe or duct passing through a fire-rated wall creates a breach. Our firestopping systems seal it to stop fire, heat and smoke, in accordance with Swiss VKF/AEAI standards.
Flexible firestopping for walls and slabs
Insulating panels that seal large openings in a wall or floor. Quick, clean installation that is easy to adapt when new services are added. Fire resistance: EI 30 to EI 90.
Fire-rated boxes for electrical cables
A metal box around cable penetrations that blocks fire instantly when exposed to heat. Maintenance-free, with cables that can be modified at any time. Fire resistance: EI 90.
Fire-rated sleeves for electrical cables
Our most robust solution, for heavily used cable penetrations (industry, data centres). Fire- and smoke-tight. Fire resistance: up to 120 minutes.
Fire dampers and ventilation firestopping
Sealing of ventilation ducts passing through a fire-rated wall, completed by a damper that automatically closes the duct in the event of fire. Fire resistance: RF1 to EI 90.
All our solutions are installed in line with the fire protection concept and VKF/AEAI standards, with a full compliance guarantee.
Fire-resistant boards, ceilings and partitions: fire protection from EI30 to EI180, sound insulation and structural stability in line with VKF/AEAI.
Fire-resistant cladding for carbon fibre strips: fire protection for structural reinforcements, fire resistance of 30 to 90 minutes and VKF/AEAI compliance.
Fire-rated cable trays: fire protection up to EI120, safety of escape routes and VKF/AEAI compliance.
Fire-resistant cladding for steel columns and beams: structural stability, EI30 to EI180 protection and VKF/AEAI compliance.
Smoke and heat extraction ducts: fire-rated ventilation and smoke extraction from EI30 to EI180, resistant to fire, impact and moisture, VKF/AEAI compliant.
Enclosure for return air at dampers: EI30 to EI90 fire protection for ventilation systems, compliant with VKF/AEAI requirements.
Technical insulation of pipework
Insulating covering (polyurethane, rock wool, synthetic rubber) applied to pipes to reduce heat loss and meet fire protection requirements at penetrations. Clean finish, quick installation. Classification: RF3 to RF1.
Technical insulation of ventilation ducts
The same principle applied to ventilation ducts, with enhanced sound insulation as well. Meets both fire standards (RF1, EI 30, EI 60) and energy requirements.
All our solutions are installed in line with the fire protection concept and VKF/AEAI standards, with a full compliance guarantee.
A paint that, when exposed to heat (from 130°C), swells up to 80 times its thickness to protect steel or concrete structures. Discreet and thin (0.5 to 3 mm), it preserves the architectural appearance without adding load to the structure. Fire resistance: R30 to R60.
All our solutions are installed in line with the fire protection concept and VKF/AEAI standards, with a full compliance guarantee.
A sprayed coating (mortar or mineral wool) applied to load-bearing structures to delay their failure in the event of fire. Two processes depending on requirements: immediate effect with no swelling, or a more refined finish with the added benefit of sound insulation. Fire resistance: R30 to R90.
All our solutions are installed in line with the fire protection concept and VKF/AEAI standards, with a full compliance guarantee.
Blowing of insulation (glass wool, rock wool, cellulose) into service shafts, building voids, roof spaces or floors. Improves both fire safety and thermal and acoustic insulation, including in small, hard-to-reach cavities. Reaction to fire: RF3 to RF1.
All our solutions are installed in line with the fire protection concept and VKF/AEAI standards, with a full compliance guarantee.
A decorative mineral wool coating sprayed onto ceilings and walls, designed for public spaces (libraries, concert halls, gyms, places of worship). Exceptional sound absorption, smooth or lightly textured finish, without overloading the structure. Fire classification: RF1, compliant with the SIA 181 standard.
All our solutions are installed in line with the fire protection concept and VKF/AEAI standards, with a full compliance guarantee.
A flexible seal fitted around doors or at the junctions between walls and slabs, preventing fire, heat and smoke from passing through these joints. Neat finish, sound insulation included, quick installation. Fire resistance: EI 30 to EI 120.
Two solutions for pipe penetrations: compensators, for pipes subject to high expansion or vibration (heavy industry), and collars, which close automatically when exposed to heat to seal plastic pipes (PVC, PE, PP). Fire resistance: EI 90 to EI 180.
All our solutions are installed in line with the fire protection concept and VKF/AEAI standards, with a full compliance guarantee.
Fire protection elements are not designed to bear human loads. To prevent falls and secure walkways, Fire System SA offers suitable solutions:
Benefits
Suva directive: any opening larger than 30 cm in a floor must be protected once the technical installations are in place.
We perform industrial sandblasting work, with various levels of surface preparation ranging from Sa 1 to Sa 3, in accordance with the SN EN ISO 8501-1 standard.
Our teams are also trained and certified to perform decontamination work, particularly for the treatment of surfaces containing lead, chromium, PCBs, and other substances.
We operate in compliance with current safety standards and environmental requirements, ensuring risk management and the protection of people.
To ensure responsible management of waste generated by our operations, we work exclusively with approved and recognized treatment and recycling facilities.
Fire protection built in from the start of construction
Safety, sealing and innovation from the structural works onwards!
Developed by Fire System, the FS-Bloc is an innovative solution that revolutionises the handling of service penetrations in concrete elements.
Watertight and robust, the FS-Bloc secures your sites as soon as it is installed. Able to bear a load of up to 150 kg, it helps prevent fall hazards while providing fire protection from the construction phase.
Built directly into the structural works, it makes it possible to plan for future technical installations, reduce later interventions and optimise costs and timelines.
FS-Bloc: one solution to secure your sites, protect your buildings and build more intelligently.
Fire protection does not end when the building is handed over. In line with VKF/AEAI requirements, Fire System SA offers a complete audit and maintenance service, designed to support buildings throughout their operational life.
Audit: understand and prioritise
The audit provides a snapshot of the current situation, sets priorities, anticipates maintenance needs and estimates the cost of restoring compliance. It is a decision-making tool for owners, operators and property managers.
Digitally enhanced maintenance
Fire System SA relies on advanced digital tools to ensure full traceability:
A tailor-made offer for every site